← Back to work
  • Finite elements
  • Patents
  • Mechanical design

What are the central tubes of a LEGO brick for? A finite element analysis

Question

A LEGO brick has three hollow cylinders inside. The 1958 patent says where they go, but not how much they contribute.

What I did

I rebuilt the brick from the patent and calculated the grip with and without the tubes using finite elements.

Answer

The tubes provide 61 % of the grip and almost triple it. Without them, a brick offset by one row does not hold.

Own project · 2026 · Patent US 3,005,282, expired · 2x4 brick

The case in one minute (in Spanish): the question, the patent, the tube rule, the model, the mesh, the analysis and the answer. The video loads from YouTube when you click. Watch on YouTube.

The question

Turn a 2x4 LEGO brick over and you will see three hollow cylinders in the middle. The patent calls them tubes, and so will I. What are they for? This case answers that question with a finite element analysis.

According to the company's own history, until 1958 every brick was hollow. Models were not very stable and complaints came in from the markets. On 23 January the options were discussed and Godtfred Kirk Christiansen drew several, among them the tubes. On 28 January the patent application was filed in Denmark.

The history says the tubes give stability. I wanted to know how much, and where it comes from: what share of the grip comes from the tubes and what share from the walls.

What the patent says, and what it does not

Patent US 3,005,282 was filed in 1958 and granted in 1961. It has now expired and is a public document. It does not contain a single dimension. It contains a rule: the tube is centred between four studs and its cross-section touches all four, and each stud touches a tube and a wall at the same time. Claim 4 calls it tangential contact at three points.

It resembles work with inventors: you start from a text and drawings without dimensions. I redrew the two sheets from the 3D model, in the format the Spanish Patent Office (OEPM) asks for today and with the same reference numbers as the original patent (10, 11, 12, 15, 21 and 22). Producing drawing sheets from a model is part of the patents and inventors service.

Sheet 1: the brick seen from above (FIG. 1) and from below, with its three tubes (FIG. 2).
Sheet 2: plan view (FIG. 3) and section of two bricks fitted together (FIG. 4). The numbers are those of the patent.

From the rule to the dimensions

I started from six assumed dimensions, all typical of current bricks: stud pitch (8.0 mm), stud diameter (4.8 mm) and height (1.7 mm), body height (9.6 mm), top plate thickness (1.0 mm) and clearance between bricks (0.2 mm). Everything else follows from the patent's rule. The wall comes out at 1.5 mm and the tube at 6.51 mm outside diameter. I did not choose either of those two dimensions.

Turning a geometric rule into a dimensioned model is ordinary mechanical design. I checked it against three references. The wall matches what the community measures on today's brick. The tube matches the usual formula, √2 · pitch − stud diameter. And the model weighs 2.41 g in ABS, against roughly 2.3 g for a current 2x4.

I modelled the patent's brick, not today's, which has internal ribs, hollow studs and fillets. That way everything I calculate comes from the public document and those six dimensions.

Two 2x4 bricks from the model, one offset from the other as in FIG. 6 of the patent
Two bricks of the model in the position of FIG. 6 of patent US 3,005,282.

How I calculated it

To find out what the tubes do, I calculated the same pair of bricks with and without tubes, in two positions: aligned and offset by one row, as in FIG. 6 of the patent.

With the nominal dimensions, stud and tube are exactly tangent: clearance and squeeze are both zero. The real grip comes from the manufacturing interference, a few thousandths of a millimetre. That is why every case is compared at the same interference, 0.01 mm.

I set it up as an interference contact in a finite element analysis with CalculiX. By symmetry I calculate a quarter of two 2x4 bricks. That quarter contains both kinds of stud: the corner stud, which touches two walls and a tube, and the central stud, which touches one wall and two tubes. That lets me separate the force from each wall and each tube. The material is linear elastic ABS (E = 2,300 MPa, ν = 0.35, friction 0.35) with catalogue values, not measured ones.

The interference is introduced by growing the radius of the studs, a common way of setting up press fits without simulating the insertion. The force to separate the bricks is friction times the sum of the normal contact forces. I did not simulate the pull with friction on the full brick: with the solver available, each case would have taken hours. In the verification case, the simulated pull matches that product to within 1.5 %, so the cases were run with the interference only.

Checking the method before trusting it

I applied the same method to a case with an exact solution: a solid shaft inside a tube, solved with the Lamé equations. The contact pressure deviates by 0.2 % and the extraction force by 0.9 %.

I made a mistake along the way. The first version integrated the contact pressure at the nodes and gave about 940 N in total, over 300 N to separate two bricks. That did not match the stresses: with those forces the walls would be at tens of MPa in bending, and the model showed 12 MPa at most. The cause is that the contact between stud and wall is a line, narrower than one mesh element, and the pressure extrapolated to the nodes comes out inflated. I solved it by asking the program for the total force of each contact pair, which comes from equilibrium and does not depend on that extrapolation. I checked it against Lamé again and the difference was 0.6 %.

The answer: the tubes hold the brick

The tubes provide 61 % of the grip. Without them, the same brick grips almost three times less: 9 N against 26 N.

61 %Of the grip comes from the tubes
×2.9Grip with tubes versus without
8.3 NOffset by one row, with tubes
0 NOffset by one row, without tubes
Bar chart with the separation force in four configurations: aligned and offset, with and without tubes
Force to separate the bricks with 0.01 mm of interference, in four configurations.

Without tubes, the walls do all the work, and they do it badly away from the corners. At the middle of the long wall the stud hardly pushes (0.6 N, against 3.3 N near the corner), because there the wall bends like a sheet. The tubes give each stud a second, stiff support on the side opposite the wall.

With the bricks offset by one row the difference is total. Without tubes it does not grip at all: the row of studs that enters touches only one wall, nothing squeezes it from the other side and the brick moves until it stops pushing. With tubes, that same row is pinched between wall and tube and holds 8.3 N with just four studs.

That is the answer: the tubes are what let the bricks join in any relative position, as the patent puts it, and they are the stability the hollow bricks before 1958 lacked.

Brick without tubes seen from below with the deformation magnified: only the walls work
The same brick without tubes: only the walls work. Deformation ×150.
Brick with tubes offset by one row: only the wall on the engaged side bulges
Offset by one row: only the wall on the engaged side bulges. Deformation ×150.
Low stress · 0 MPaHigh · 10 MPa

How hard it grips: each micron adds about 2.6 N

With 0.01 mm of interference, the model gives about 26 N to separate two aligned 2x4 bricks, the weight of roughly 2.6 kg. The relationship is linear: doubling the interference multiplies the force by 2.03. As a rule of thumb, each micron of interference adds about 2.6 N to the grip of a 2x4.

Upper brick seen from below with the deformation magnified: the walls bulge and the three tubes are squeezed
Low stress · 0 MPaHigh · 10 MPa
Upper brick seen from below, deformation ×150: the walls bulge and the tubes are squeezed. Interference of 0.01 mm.
Chart of the force to separate a 2x4 against interference, with and without tubes
Force to separate a 2x4 against interference per contact. The points are calculated; the dashed line is extrapolated.

Away from the edges, the material works far below its limit: the 99th percentile of the von Mises stress is about 5 MPa, against an ABS limit of about 40 MPa. At the stud edge there are peaks of 12 to 26 MPa that rise as the mesh is refined. That is a sharp-edge singularity, not a physical value, and a real brick has chamfers that soften it.

Limits

The calculation does not certify a real part and does not replace a test. These are its limits.

  • The model is the patent's brick, not the one sold today.
  • The real interference depends on the machine, the mould and the batch, and I have not found an official published figure. That is why the result is a curve against interference and not a single value.
  • ABS is modelled as linear and without creep. Under constant load it relaxes over time, which could explain why bricks that stay assembled for years grip less. The model does not calculate that.
  • The modulus and the friction are catalogue values, and the separation force is proportional to friction.
  • I do not simulate assembly: the insertion force depends on chamfers and fillets that the patent does not define.
  • The 0.25 mm mesh overestimates the forces by around 5 %. With 0.15 mm, the 26 N become about 25 N, and the comparisons between cases barely change.
  • I have not validated the absolute figures with measurements, and I have not found any reliable published measurement of the separation force. That is why I write them as “with 0.01 mm of interference, the model gives…”. The comparisons between cases, such as the 61 % or the ×2.9, depend much less on those data.

Sources

Patent US 3,005,282, G. K. Christiansen, “Toy building brick”, filed on 28 July 1958 (Danish priority of 28 January 1958) and granted on 24 October 1961. The 1958 account comes from the company's official history. The measured dimensions of today's brick come from the enthusiast community.

LEGO® is a trademark of The LEGO Group, which does not sponsor or endorse this analysis.

CalculiXgmshCadQueryPythonPatent readingOEPM drawing sheets

Next step

Do you have a press-fit part, a clip or a snap fit that comes loose or breaks?

Send me photos and whatever you know about it. I'll tell you how I would analyse it.